SUMMARY:The Impact of Numerical Resolution on the Accuracy of 2D Irregula
 r Cell Detonation Simulations
DESCRIPTION:Speaker: Max Hanssen\n\nThis study investigates the effect of
  resolution on detonation dynamics in numerical simulations. One- and two
 -dimensional (1D and 2D) simulations were performed for resolutions betwe
 en 10 and 300 grid points per ZND induction-zone length for undiluted and
  diluted stoichiometric mixtures of methane-oxygen and hydrogen-oxygen. S
 pecific properties observed include cell irregularity (measured using the
  standard deviation of cell angle)\, average cell size\, detonation speed
 \, the induction zone in 1D\, and a characteristic length scale in the st
 reamwise direction in 2D simulations. The standard deviation of cell angl
 e shows that when increasing resolution there is a sudden transition to i
 rregularity. However\, this transition can occur at different resolutions
  for different mixtures. Detonation speed stays largely constant\, althou
 gh there is a slight decreasing trend with increasing resolution. 1D simu
 lations show that the distance between the leading shock and the maximum 
 heat release gradient increases with resolution up to 80 grid points per 
 induction-zone length\, where it converges at a value close to the ZND in
 duction-zone length. For the 2D methane-air simulations\, it was observed
  that low resolution smears out the shock and reaction zone. This leads t
 o the temperature artificially increasing earlier than expected\, leading
  to a sooner rapid heat\nrelease. A too-low resolution can even suppress 
 transverse waves and cellular structures entirely. Unburnt pockets and ir
 regularity are observed at 80 grid points per induction-zone length\, and
  a resolution of 300 grid points per induction-zone length shows more pre
 cise vortices and small-scale effects. It has been concluded that capturi
 ng the global behavior of irregular-cell detonations requires at least 40
 -80 grid points per ZND induction-zone length (depending on the mixture).